Purpose
The RAFT manifest defines the relationships among samples, patients, and datasets. Multiple samples are required per patient and each sample plays a crucial role in predicting pMHCs. For example, the normal and tumor DNA samples are required for calling somatic variants while the RNA tumor sample is essential in determining tumor expression of a variety of tumor antigens (ERVs, viruses, somatic variants, splice variants, and fusions).
A RAFT manifest for LENS requires the following samples per patient:
At least one tumor DNA sample
At least one normal DNA sample
At least one tumor RNA sample
At least one tissue-matched, patient-matched normal RNA sample (Optional)
At least one tissue-matched, non-patient-matched normal RNA sample (e.g. GTEx)
RAFT manifests may contain one or more patients. Many computer clusters will allow for multiple patients to be run in parallel to reduce run time.
Sample, patient, and dataset heirarchy
The organizational hierarchy within RAFT follows
Sample ∈ Patient ∈ Dataset
In other words, samples belong to patients (patients can have multiple samples) and patients belong to datasets (datasets can have multiple patients). This hierarchy allows for accurate and efficient combining of samples for processing.
Contents
A RAFT manifest must have at least the columns defined in the table below. Columns can be in any order and other columns containing non-RAFT metadata are also allowed.
Column |
Description |
Allowed values |
|---|---|---|
Dataset |
Name for collection of patients |
Free text |
Patient Name |
Name for collection of samples |
Free text (except |
Run Name |
Name for the specific sample |
Free text (see note below) |
File Prefix |
Base name (or full path) of input files |
Free text |
Sequencing Method |
Sequencing protocol for sample |
(RNA-seq, WES, WXS, WGS) |
Normal |
Is the sample normal or abnormal (tumor)? |
(TRUE, FALSE) |
Note
A sample’s Run_Name is instrumental in guiding samples through some RAFT workflows.
A sample’s Run_Name should have a two-letter prefix that describes the type of
sample and a delimiter (- or _) followed by an arbitrary unique identifier. The first letter of the prefix
is either a (for abnormal) or n (for normal). The second letter is either r (for
RNA) or d (for DNA). For example, a sample with an ar- (or ar_) prefix is an abnormal
(tumor) RNA sample while a sample with a nd- prefix is a normal DNA sample.
Note
The patient name UNIV (short for UNIVersal) is reserved and intended for
samples that are expected to be shared among patients. For example, if not all of your
patients have a patient-matched, tissue-matched normal RNA sample, then an
external tissue-matched sample (e.g. GTEx) can be utilized with the patient name UNIV.
Patients that have the apprpriate patient-matched, tissue-matched normal RNA
sample will use their own sample while other patients will use the UNIV
sample instead.
Each line in the manifest after the header corresponds to a sample and
provides the necessary data for running a RAFT workflow. The samples described
within the manifest may, in some cases, be effectively independent (as in, the
workflow does not attempt to pair samples from a patient), but in other cases,
users must be careful that samples are properly labeled. For example, somatic
variant calling generally requires a normal DNA sample and a tumor DNA
sample. For RAFT to properly pair these samples together, they must have
the correct sample prefix (nd- for the DNA tumor sample and nd- for the DNA
normal sample) and be paired with the patient (Patient_Name field) and dataset
(Dataset field). Consider the following example:
Patient_Name Run_Name Dataset File_Prefix Sequencing_Method Normal
Pt01 ad-Pt01-03A AML 9f7f7 WES FALSE
Pt01 nd-Pt01-11A AML 8e74a WES TRUE
Pt01 ar-Pt01-03A AML cdb288 RNA-Seq FALSE
UNIV nr-CTRL AML CD34-U RNA-Seq TRUE
Note
Both the tumor DNA sample (ad-Pt01-03A) and the normal DNA (nd-Pt01-11A) sample belong to the same patient (Pt01) and the same dataset (AML).
Complex sample sets
Users may encounter situations that require more than one sample
per sample type per patient. For example, users may have a single set of DNA
samples (normal DNA and tumor DNA), but may have multiple RNA-seq samples (e.g.
multiple timepoints). Users can use RAFT’s subjoin functionality to support
these cases. Specifically, each sample in the manifest requires an additional
column (Group). By default, LENS assumes all samples belonging to a single
pat_name should all be used together (like the example above). Users should
use group identifiers to ensure groups of samples are used together. For example,
Patient_Name Run_Name Dataset File_Prefix Sequencing_Method Normal Group
Pt01 ad-Pt01-03A AML 9f7f7 WES FALSE 1-2
Pt01 nd-Pt01-11A AML 8e74a WES TRUE 1-2
Pt01 ar-Pt01-03A AML cdb288 RNA-Seq FALSE 1
Pt01 ar-Pt01-03B AML cdb289 RNA-Seq FALSE 2
UNIV nr-CTRL AML CD34-U RNA-Seq TRUE *
Note
UNIV samples can be assigned a * Group value which will allow them
to be paired to all possible combinations (where a patient-specific sample of
that type is not already present). UNIV samples can also be limited to
specific Group use Group identifiers (e.g. 1-2) as well.
This scenario may depict an instance where we have a patient (Pt01) that
has a DNA normal sample, a DNA tumor sample, and two RNA-seq samples. For
this example, let’s assume the first RNA-seq sample (ar-Pt01-03A) is a
pre-treatment sample while the second RNA-seq sample (ar-PT01-03B) is a
post-treatment sample and you, as an investigator, are interested in
understanding how treatment affected the tumor antigen landscape. In this case,
LENS will be run on two distinct sample sets (tumor RNA-seq samples bolded for
emphasis):
- The pre-treatment sample set:
ad-Pt01-03A
nd-Pt01-11A
ar-Pt01-03A
nr-CTRL
and the post-treatment sample set:
ad-Pt01-03A
nd-Pt01-11A
ar-Pt01-03B
nr-CTRL
Both of these sample sets will have their own individual LENS report after the completion of the LENS workflow.
Note
Groups identifiers do not have to be numbers (like the example above).
The identifiers can also be descriptive identifiers (e.g. pre-treatment
and post-treatment).
Checking manifest
LENS automtically checks manifest integrity when raft is run in either
run-ots or run-workflow modes.
Users can manually verify the integrity of their manifest files using:
raft.py check-manifest -m </PATH/TO/MANIFEST>